Automation of a variable wavelength controlled HMI ultraviolet light generator
Main Article Content
Abstract
In the present investigation, the main objective was to perform a UV light wavelength control on a prototype, analyzing its optics, the reference of which is the Perkin Elmer 781 spectrophotometer, used in decontamination analysis of surfactant and photodegradation waters, to which the generator has been redesigned, determining the frequency range, reducing the environmental impact, through the implementation of HMI, whose applied methodology, to carry out the automation process whose application approach is determined through the graduation and decontamination photo of the water, presenting a redesign for the generation of UV wavelengths within the electrical and electronic part through Newton's interpolation, reducing the error to 0.05% least squares of 3.32%, optimizing the control of motors with an HMI connection, using which the generated wavelength is visualized facilitating the navigation and the control of the motors granting to the operator direct interaction with the equipment, obtaining as a result the improvement of the original system, varying the sensors and actuators to obtain wavelengths from 500 nm to 700 nm, which allows work to be carried out on the decontamination of water and the effectiveness of the system.
Downloads
Article Details
References
Elmer, P. (2004). Perkin Elmer. Obtenido de Lambda 650, 800, and 950, Spectrophotometers: Disponible en: https://www.perkinelmer.com/lab-solutions//resources/docs/BRO_L ambda950850650Americas.pdf 8-12p.
Garcés, L., Mejía, E., & Santamaría, J. (2011). Revista. Obtenido de Universidad Lasallista: Disponible en: http://www.lasallista.edu.co/fxcul/media/pdf/Revista/Vol1n1/083-92%20La%20fotocat%C3%A1lisis%20como%20alternativa%20para%20el%20tratamiento.pdf . 10-15p.
Granada, U. (2015). Espectroscopia. Obtenido de Espectroscopia Ultravioleta visible. Disponible en: http://www.ugr.es/~quiored/espec/uv.htm
Harris, D. (2006). Análisis Químico Cuantitativo. New York: Reverte.
Paullan, D. (2015). Degradación del fenol presente en las descargas de aguas residuos industriales Shushufindi mediante fotoxidación catalítica homogénea y heterogénea descontaminación de descargas. Riobamba: ESPOCH. 15 -16 p.
Pérez, D., y Rengifo, J. (2011). villamor. Obtenido de espejosplanosyesfericos: http://villamorespejosplanosyesfericos.blogspot.com/
Peri, C. (2015). Instituto Argentino de Radioastronomía. Disponible en: http://www.iar.unlp.edu.ar/divulgacion/art-difu-21.htm
Requena, A., y Zúñiga, J. (2004). Espectroscopía. Murcia: Pearson. 12-17p
RockwellAutomation. (2014). rockwellautomation. Obtenido de iterature/documents: http://literature.rockwellautomation.com/idc/groups/literature/documents/br/2080-br001_-es-p.pdf
Sirtori, C., López, A., & Rodríguez, S. (2010). Evaluación analítica de procesos de transformación biológica, fotoquímica y fotocatalítica de fármacos en agua. Editorial Ciemat.
Skoog, D. A. (2008). Principios Análisis Instrumental. México: CENGAGE.
Skoog, D., Holler, F., & Crouch, S. (2008). Principios de análisis Instrumental. México: CENGAGE.
Todorobot. (2016). Todorobot. Obtenido de motores, Disponible en: http://www.todorobot.com.ar/tutorial-sobre-motores-paso-a-paso-stepper-motors/
Viticodoc. (2010). Scribd. Campos visuales normales. Disponible en: http://es.scribd.com/doc/35067879/FISICA-Y-OPTICA#scribd
Yaulema, J., y Rosero, J., (2016). Automatización de un generador de luz ultravioeta visible de longitud de onda variable, controlado con un HMI, (Tesis Pregrado).Quito. Universidad Salesiana.
Zúñiga, A. R. (2004). Espectroscopía. En A. R. Zuñiga, Espectroscopía. Murcia: Pearson. 39 p.